SUNACE
Australia · Leading through quality
Sun Ace Australia Pty Ltd
32-38 Remington Drive, Dandenong South VIC 3175
ABN 52 006 388 102 · +61 3 9702 9444 · sunace@sunace.com.au
Certificate of Analysis
COA-25-0834
Product
SAK-BZL40
SAK-BZL 40 · liquid Ba/Zn, low phenol, flexible
Liquid mixed-metal stabilisers
Batch
B25-0834
- Manufactured
- 24 Oct 2025
- Best before
- 24 Oct 2027
- Quantity made
- 3,969 kg
- Works order
- WO-2025-0834
Liquid mixed-metal release
QP-LIQUID
Liquid Ba/Zn and Ca/Zn grades, viscosity and colour on the drum.
Tested against
The published specification for SAK-BZL40, released under QP-LIQUID.
| Test | Specification | Result | Off target | Outcome |
|---|---|---|---|---|
| Yield | 97.50 to 100.00 % | 99.59 % | — | Pass |
| Peak temperature | 128.0 to 142.0 °C | 134.0 °C | — | Pass |
| Fusion time | 54.0 s ±3% | 54.1 s | +0.19% | Pass |
| Torque, peak | 42.0 Nm ±3% | 42.1 Nm | +0.24% | Pass |
| Viscosity 25°C | 180 to 340 mPa·s | 235 mPa·s | — | Pass |
| Colour, initial ΔE | 0.00 to 3.50 ΔE | 1.12 ΔE | — | Pass |
| Metal content | 6.20 to 7.40 % | 6.76 % | — | Pass |
| Appearance vs standard | 1 to 1 pass | Conforms | — | Pass |
Part batches supplied to Polyflor Australia Pty Ltd
- SO-00921 14 Mar 2026 · 334 kg · 1 palletB25-0834-P01
- SO-01044 12 Jul 2026 · 2,552 kg · 6 palletsB25-0834-P02B25-0834-P03B25-0834-P04B25-0834-P05B25-0834-P06B25-0834-P07
10 pallets came off this run. Each carries its own label, so a claim can be answered against the pallets that were delivered rather than the whole batch.
Released by
Priya Raman
25 Oct 2025 at 10:49am
Made on RX-02 by Sione Naufahu
Despatched against
- Polyflor Australia Pty Ltd SO-01044 · 2,552 kg
- Polyflor Australia Pty Ltd SO-00921 · 334 kg
- The goods described were manufactured under a quality system certified to ISO 9001:2015.
- A retained sample of this batch is held for the shelf life of the product.
Sun Ace Australia Pty Ltd, ABN 52 006 388 102. Results of testing carried out on the batch named above under quality plan QP-LIQUID. Results relate only to the batch tested. COA-GENERAL