SUNACE
SUNACE
Certificate of analysis B25-0908 ACEGUARD HT 8 · hydrotalcite co-stabiliser blend
July 2026 close · posted live Mon 3 Aug 2026

SUNACE

Australia · Leading through quality

Sun Ace Australia Pty Ltd
32-38 Remington Drive, Dandenong South VIC 3175
ABN 52 006 388 102 · +61 3 9702 9444 · sunace@sunace.com.au

Certificate of Analysis

COA-25-0908

Product

ACEGUARD-HT8

ACEGUARD HT 8 · hydrotalcite co-stabiliser blend

Speciality additives

Batch

B25-0908

Manufactured
13 Dec 2025
Best before
13 Dec 2027
Quantity made
2,468 kg
Works order
WO-2025-0908

Metallic stearate release

QP-STEARATE

Conforms to specification

Precipitated and fused stearates. Metal content and sieve residue decide the grade.

Tested against

The published specification for ACEGUARD-HT8, released under QP-STEARATE.

This batch went to 2 customers. Issue the certificate for Tycab Australia Pty Ltd · Olex Australia Pty Ltd

Test Specification Result Off target Outcome
Yield 97.50 to 100.00 % 99.30 % — Pass
Peak temperature 128.0 to 142.0 °C 136.8 °C — Pass
Metal content 6.20 to 7.40 % 6.70 % — Pass
Moisture 0.00 to 1.50 % 0.39 % — Pass
Bulk density 260 to 400 g/L 316 g/L — Pass
Sieve residue 75 µm 0.00 to 0.50 % 0.14 % — Pass
Melting point 145.0 to 165.0 °C 156.0 °C — Pass
Free fatty acid 0.00 to 1.20 % 0.35 % — Pass

Part batches supplied to Tycab Australia Pty Ltd

  • SO-00827 18 Dec 2025 · 1,322 kg · 2 pallets
    B25-0908-P01B25-0908-P03

3 pallets came off this run. Each carries its own label, so a claim can be answered against the pallets that were delivered rather than the whole batch.

Released by

Vinh Le

14 Dec 2025 at 10:29am

Made on BL-02 by Sione Naufahu

Despatched against

  • Tycab Australia Pty Ltd SO-00827 · 1,322 kg
  • Olex Australia Pty Ltd SO-00823 · 191 kg
  • The goods described were manufactured under a quality system certified to ISO 9001:2015.
  • A retained sample of this batch is held for the shelf life of the product.

Sun Ace Australia Pty Ltd, ABN 52 006 388 102. Results of testing carried out on the batch named above under quality plan QP-STEARATE. Results relate only to the batch tested. COA-GENERAL