Certificate of Analysis
COA-25-0933
Product
ACEGUARD-HT8
ACEGUARD HT 8 · hydrotalcite co-stabiliser blend
Speciality additives
Batch
B25-0933
- Manufactured
- 25 Dec 2025
- Best before
- 25 Dec 2027
- Quantity made
- 2,479 kg
- Works order
- WO-2025-0933
Metallic stearate release
QP-STEARATE
Precipitated and fused stearates. Metal content and sieve residue decide the grade.
Tested against
The published specification for ACEGUARD-HT8, released under QP-STEARATE.
| Test | Specification | Result | Off target | Outcome |
|---|---|---|---|---|
| Yield | 97.50 to 100.00 % | 99.26 % | — | Pass |
| Peak temperature | 128.0 to 142.0 °C | 135.1 °C | — | Pass |
| Metal content | 6.20 to 7.40 % | 6.62 % | — | Pass |
| Moisture | 0.00 to 1.50 % | 0.69 % | — | Pass |
| Bulk density | 260 to 400 g/L | 338 g/L | — | Pass |
| Sieve residue 75 µm | 0.00 to 0.50 % | 0.07 % | — | Pass |
| Melting point | 145.0 to 165.0 °C | 157.8 °C | — | Pass |
| Free fatty acid | 0.00 to 1.20 % | 0.34 % | — | Pass |
Part batches supplied to Olex Australia Pty Ltd
- SO-00863 24 Jan 2026 · 1,344 kg · 2 palletsB25-0933-P01B25-0933-P03
3 pallets came off this run. Each carries its own label, so a claim can be answered against the pallets that were delivered rather than the whole batch.
Released by
Priya Raman
26 Dec 2025 at 10:32am
Made on BL-02 by Malcolm Rees
Despatched against
- Olex Australia Pty Ltd SO-00863 · 1,344 kg
- The goods described were manufactured under a quality system certified to ISO 9001:2015.
- A retained sample of this batch is held for the shelf life of the product.
Sun Ace Australia Pty Ltd, ABN 52 006 388 102. Results of testing carried out on the batch named above under quality plan QP-STEARATE. Results relate only to the batch tested. COA-GENERAL