SUNACE
Australia · Leading through quality
Sun Ace Australia Pty Ltd
32-38 Remington Drive, Dandenong South VIC 3175
ABN 52 006 388 102 · +61 3 9702 9444 · sunace@sunace.com.au
Certificate of Analysis
COA-26-0084
Product
ACEGUARD-HT8
ACEGUARD HT 8 · hydrotalcite co-stabiliser blend
Speciality additives
Batch
B26-0084
- Manufactured
- 04 Jan 2026
- Best before
- 04 Jan 2028
- Quantity made
- 2,459 kg
- Works order
- WO-2026-0084
Metallic stearate release
QP-STEARATE
Precipitated and fused stearates. Metal content and sieve residue decide the grade.
Tested against
The published specification for ACEGUARD-HT8, released under QP-STEARATE.
This batch went to 2 customers. Issue the certificate for Prysmian Australia Pty Ltd · Olex Australia Pty Ltd
| Test | Specification | Result | Off target | Outcome |
|---|---|---|---|---|
| Yield | 97.50 to 100.00 % | 99.21 % | — | Pass |
| Peak temperature | 128.0 to 142.0 °C | 135.1 °C | — | Pass |
| Metal content | 6.20 to 7.40 % | 6.62 % | — | Pass |
| Moisture | 0.00 to 1.50 % | 0.80 % | — | Pass |
| Bulk density | 260 to 400 g/L | 318 g/L | — | Pass |
| Sieve residue 75 µm | 0.00 to 0.50 % | 0.02 % | — | Pass |
| Melting point | 145.0 to 165.0 °C | 155.2 °C | — | Pass |
| Free fatty acid | 0.00 to 1.20 % | 0.51 % | — | Pass |
Part batches supplied to Prysmian Australia Pty Ltd
- SO-00986 08 May 2026 · 1,608 kg · 1 palletB26-0084-P02
3 pallets came off this run. Each carries its own label, so a claim can be answered against the pallets that were delivered rather than the whole batch.
Released by
Vinh Le
05 Jan 2026 at 10:46am
Made on BL-02 by Anthony Jarvis
Despatched against
- Prysmian Australia Pty Ltd SO-00986 · 1,608 kg
- Olex Australia Pty Ltd SO-00863 · 370 kg
- The goods described were manufactured under a quality system certified to ISO 9001:2015.
- A retained sample of this batch is held for the shelf life of the product.
Sun Ace Australia Pty Ltd, ABN 52 006 388 102. Results of testing carried out on the batch named above under quality plan QP-STEARATE. Results relate only to the batch tested. COA-GENERAL