SUNACE
Australia · Leading through quality
Sun Ace Australia Pty Ltd
32-38 Remington Drive, Dandenong South VIC 3175
ABN 52 006 388 102 · +61 3 9702 9444 · sunace@sunace.com.au
Certificate of Analysis
COA-26-0140
Product
SAK-BZL40
SAK-BZL 40 · liquid Ba/Zn, low phenol, flexible
Liquid mixed-metal stabilisers
Batch
B26-0140
- Manufactured
- 13 Feb 2026
- Best before
- 13 Feb 2028
- Quantity made
- 3,983 kg
- Works order
- WO-2026-0140
Liquid mixed-metal release
QP-LIQUID
Liquid Ba/Zn and Ca/Zn grades, viscosity and colour on the drum.
Tested against
The published specification for SAK-BZL40, released under QP-LIQUID.
This batch went to 2 customers. Issue the certificate for Welvic Australia Pty Ltd · Polyflor Australia Pty Ltd
| Test | Specification | Result | Off target | Outcome |
|---|---|---|---|---|
| Yield | 97.50 to 100.00 % | 99.24 % | — | Pass |
| Peak temperature | 128.0 to 142.0 °C | 134.8 °C | — | Pass |
| Fusion time | 54.0 s ±3% | 53.9 s | -0.19% | Pass |
| Torque, peak | 42.0 Nm ±3% | 41.6 Nm | -0.95% | Pass |
| Viscosity 25°C | 180 to 340 mPa·s | 225 mPa·s | — | Pass |
| Colour, initial ΔE | 0.00 to 3.50 ΔE | 1.43 ΔE | — | Pass |
| Metal content | 6.20 to 7.40 % | 6.79 % | — | Pass |
| Appearance vs standard | 1 to 1 pass | Conforms | — | Pass |
Part batches supplied to Welvic Australia Pty Ltd
- SO-01046 18 Jul 2026 · 2,000 kg · 4 palletsB26-0140-P03B26-0140-P04B26-0140-P05B26-0140-P06
10 pallets came off this run. Each carries its own label, so a claim can be answered against the pallets that were delivered rather than the whole batch.
Released by
Vinh Le
14 Feb 2026 at 10:20am
Made on RX-02 by Sione Naufahu
Despatched against
- Welvic Australia Pty Ltd SO-01046 · 2,000 kg
- Polyflor Australia Pty Ltd SO-00921 · 580 kg
- The goods described were manufactured under a quality system certified to ISO 9001:2015.
- A retained sample of this batch is held for the shelf life of the product.
Sun Ace Australia Pty Ltd, ABN 52 006 388 102. Results of testing carried out on the batch named above under quality plan QP-LIQUID. Results relate only to the batch tested. COA-GENERAL