SUNACE
Australia · Leading through quality
Sun Ace Australia Pty Ltd
32-38 Remington Drive, Dandenong South VIC 3175
ABN 52 006 388 102 · +61 3 9702 9444 · sunace@sunace.com.au
Certificate of Analysis
COA-26-0172
Product
ACEGUARD-HT8
ACEGUARD HT 8 · hydrotalcite co-stabiliser blend
Speciality additives
Batch
B26-0172
- Manufactured
- 10 Mar 2026
- Best before
- 09 Mar 2028
- Quantity made
- 2,462 kg
- Works order
- WO-2026-0172
Metallic stearate release
QP-STEARATE
Precipitated and fused stearates. Metal content and sieve residue decide the grade.
Tested against
The published specification for ACEGUARD-HT8, released under QP-STEARATE.
This batch went to 2 customers. Issue the certificate for Prysmian Australia Pty Ltd · Tycab Australia Pty Ltd
| Test | Specification | Result | Off target | Outcome |
|---|---|---|---|---|
| Yield | 97.50 to 100.00 % | 99.01 % | — | Pass |
| Peak temperature | 128.0 to 142.0 °C | 135.6 °C | — | Pass |
| Metal content | 6.20 to 7.40 % | 6.63 % | — | Pass |
| Moisture | 0.00 to 1.50 % | 0.47 % | — | Pass |
| Bulk density | 260 to 400 g/L | 300 g/L | — | Pass |
| Sieve residue 75 µm | 0.00 to 0.50 % | 0.08 % | — | Pass |
| Melting point | 145.0 to 165.0 °C | 157.4 °C | — | Pass |
| Free fatty acid | 0.00 to 1.20 % | 0.65 % | — | Pass |
Part batches supplied to Prysmian Australia Pty Ltd
- SO-00986 08 May 2026 · 644 kg · 1 palletB26-0172-P01
3 pallets came off this run. Each carries its own label, so a claim can be answered against the pallets that were delivered rather than the whole batch.
Released by
Vinh Le
11 Mar 2026 at 10:49am
Made on BL-02 by Sione Naufahu
Despatched against
- Prysmian Australia Pty Ltd SO-00986 · 644 kg
- Tycab Australia Pty Ltd SO-01050 · 477 kg
- The goods described were manufactured under a quality system certified to ISO 9001:2015.
- A retained sample of this batch is held for the shelf life of the product.
Sun Ace Australia Pty Ltd, ABN 52 006 388 102. Results of testing carried out on the batch named above under quality plan QP-STEARATE. Results relate only to the batch tested. COA-GENERAL