SUNACE
Australia · Leading through quality
Sun Ace Australia Pty Ltd
32-38 Remington Drive, Dandenong South VIC 3175
ABN 52 006 388 102 · +61 3 9702 9444 · sunace@sunace.com.au
Certificate of Analysis
COA-26-0239
Product
ACE-CAS10
ACE-CAS 10 · calcium stearate, PVC grade
Metallic stearates
Batch
B26-0239
- Manufactured
- 19 Apr 2026
- Best before
- 18 Apr 2028
- Quantity made
- 9,815 kg
- Works order
- WO-2026-0239
Metallic stearate release
QP-STEARATE
Precipitated and fused stearates. Metal content and sieve residue decide the grade.
Tested against
The published specification for ACE-CAS10, released under QP-STEARATE.
This batch went to 3 customers. Issue the certificate for Plastamid (Pty) Ltd · Prysmian Australia Pty Ltd · Boral Cement Ltd
| Test | Specification | Result | Off target | Outcome |
|---|---|---|---|---|
| Yield | 97.50 to 100.00 % | 99.42 % | — | Pass |
| Peak temperature | 128.0 to 142.0 °C | 133.7 °C | — | Pass |
| Metal content | 6.20 to 7.40 % | 6.70 % | — | Pass |
| Moisture | 0.00 to 1.50 % | 0.39 % | — | Pass |
| Bulk density | 260 to 400 g/L | 327 g/L | — | Pass |
| Sieve residue 75 µm | 0.00 to 0.50 % | 0.05 % | — | Pass |
| Melting point | 145.0 to 165.0 °C | 154.3 °C | — | Pass |
| Free fatty acid | 0.00 to 1.20 % | 0.34 % | — | Pass |
Part batches supplied to Boral Cement Ltd
Nothing off this run has been despatched. 2,662 kg is still on the floor.
20 pallets came off this run. Each carries its own label, so a claim can be answered against the pallets that were delivered rather than the whole batch.
Released by
Priya Raman
20 Apr 2026 at 10:38am
Made on RX-03 by Sione Naufahu
Despatched against
- Plastamid (Pty) Ltd SO-01013 · 5,514 kg
- Prysmian Australia Pty Ltd SO-01017 · 669 kg
- Boral Cement Ltd SO-01057 · 679 kg
- The goods described were manufactured under a quality system certified to ISO 9001:2015.
- A retained sample of this batch is held for the shelf life of the product.
Sun Ace Australia Pty Ltd, ABN 52 006 388 102. Results of testing carried out on the batch named above under quality plan QP-STEARATE. Results relate only to the batch tested. COA-GENERAL