SUNACE
SUNACE
Quality Trends Peak temperature · 18 releases
July 2026 close · posted live Mon 3 Aug 2026

Manufacturing

Quality Trends

Every release in the order it was made, against its specification limits.

Releases plotted

18

ACE-MGS 10 · magnesium stearate, technical grade

Average peak temperature

134.9°C

Specification 128.0 to 142.0°C · target 135.0°C

-0.1 against target

Outside specification

0

Every release inside its limits

Clean run

Process capability, Cpk

2.09

Comfortably inside the limits

σ 1.1°C

Peak temperature by batch, in the order it was made

Red bands are the specification limits, the dashed line is target.

Inside spec Near a limit Out of spec

Nothing outside the limits

Every peak temperature release in this run sat inside its specification.

The biggest movement in the run

The largest change from one job to the next.

B25-0745
24 Aug 2025 · RX-03, Anthony Jarvis
ACE-MGS10 · 2,911 kg
136.0°C
B25-0782
08 Sep 2025 · RX-03, Malcolm Rees
ACE-MGS10 · 2,925 kg
133.2°C
-2.8 on the job before
B25-0881
03 Nov 2025 · RX-03, Tui Faletau
ACE-MGS10 · 2,911 kg
136.0°C
WO-2025-0782 ran on RX-03 under Malcolm Rees.