B25-0710
Pass Main StoreACEGUARD-HT8, ACEGUARD HT 8 · hydrotalcite co-stabiliser blend. 2,471 kg made on 19 Aug 2025 against WO-2025-0710, 118 kg still on the floor, best before 19 Aug 2027.
The run, pallet by pallet
3 pallets off WO-2025-0710. A hold is recorded against the pallet, so the rest of the run stays sellable.
| # | Pallet label | kg | Status | Location | Note | |
|---|---|---|---|---|---|---|
| 1 | B25-0710-P01 | 1,000 | Despatched | Main Store | ||
| 2 | B25-0710-P02 | 1,000 | Despatched | Main Store | ||
| 3 | B25-0710-P03 | 471 | Released | Main Store |
← Backward trace
Every raw material lot consumed into this batch, and the supplier it came from. If a supplier recalls a lot, this is the list of batches it touched.
| Raw material | Supplier lot | Supplier | kg |
|---|---|---|---|
| RM-3010 Hydrotalcite, synthetic, Mg-Al | KIS-2401597 | Kisuma Chemicals B.V. | 1,530 |
| RM-3014 Zeolite 4A, dehydrated | SIN-2612198 | Sinochem Plastics Co. Ltd | 545 |
| RM-5040 Calcium stearate, bought-in, blending grade | FAC-2512323 | Faci Asia Pacific Pte Ltd | 295 |
| RM-6040 Precipitated silica, anti-caking | SIB-2402824 | Sibelco Australia Ltd | 105 |
| Charged into the batch | 2,475 kg | ||
Forward trace →
Every despatch this batch went out on. If a customer raises a complaint against a batch number, this is who else received it.
| Sales order | Customer | Despatched | kg |
|---|---|---|---|
| SO-00863 | Olex Australia Pty Ltd Tottenham VIC | 24 Jan 2026 | 1,148 |
| SO-00701 | Clover Pipelines Pty Ltd Braeside VIC | 26 Aug 2025 | 669 |
| SO-00756 | Prysmian Australia Pty Ltd Liverpool NSW | 22 Sep 2025 | 407 |
| Despatched · remaining | 2,224 · 118 kg | ||
Release record · Metallic stearate release
Tested 20 Aug 2025 by Karen Doust. Precipitated and fused stearates. Metal content and sieve residue decide the grade.
SUNACE
Australia · Leading through quality
Sun Ace Australia Pty Ltd
32-38 Remington Drive, Dandenong South VIC 3175
ABN 52 006 388 102 · +61 3 9702 9444 · sunace@sunace.com.au
Certificate of analysis
B25-0710
- Grade
- ACEGUARD-HT8
- Manufactured
- 19 Aug 2025
- Best before
- 19 Aug 2027
- Quantity
- 2,471 kg
Sun Ace Australia Pty Ltd certifies that batch B25-0710 of ACEGUARD-HT8, ACEGUARD HT 8 · hydrotalcite co-stabiliser blend, was manufactured at Dandenong South under our ISO 9001:2015 quality system and tested against quality plan QP-STEARATE (Metallic stearate release) with the following results.
| Test | Result | Specification | Method |
|---|---|---|---|
| Yield | 99.16 % | 97.5-100 % | SA-QC-YIEL |
| Peak temperature | 133.3 °C | 128-142 °C | SA-QC-TEMP |
| Metal content | 6.95 % | 6.2-7.4 % | SA-QC-META |
| Moisture | 0.69 % | 0-1.5 % | SA-QC-MOIS |
| Bulk density | 304 g/L | 260-400 g/L | SA-QC-BULK |
| Sieve residue 75 µm | 0.10 % | 0-0.5 % | SA-QC-SIEV |
| Melting point | 155.1 °C | 145-165 °C | SA-QC-MP |
| Free fatty acid | 0.33 % | 0-1.2 % | SA-QC-FFA |
Metallic stearate grades are produced from vegetable-based fatty acids and are declared free of animal substances and BSE free. A retained sample is held for 24 months from the date of manufacture. Handle in accordance with the current safety data sheet.
Released by Karen Doust
Date